Power On Delay Digital Timer
 

 


Din 48*48
TM48-4D TM Series Power On Delay Digital Timer
HELP_FILE: NO FILE
Discription:0.01S/0.1S/1S/0.1M/1M/0.1H/1H/99M59S/99H59M
Model:TM48-4D
Outline:48×48
Range0~9999
Unit
0.001S/0.01S/0.1S
1S/0.1M/1M/0.1H/1H
99M59S/99H59M
Selectable

ItemSpecification
Power Supply24VDC/AC or 90~265VAC 50/60Hz
Current Consumption5VA max.
Control OutputTwo time limit or time limit & instantaneous contact selectable
Output MethodTwo Relay 5A/250VAC
Control MethodPower on Delay
Output StatusTiming NO or NC selectable
Timing MethodIncreasing or decreasing timing selectable
Repetivity0.1% of F.S.
Setting Accuracy0.05% of F.S.
Reset Time0.1sec max.
Reset MethodPower off reset
Insulation Strength100MΩ/500VDC
Dielectric Strength2.5kV/ 1min.
Circumstance-20°C ~ +60°C , 35%~85%RH
Life of Relay20×106Times
50*60
TM50-2D TM Series Power On Delay Digital Timer
HELP_FILE: NO FILE
Discription:0.1S/1S/0.1M/1M/0.1H/1H
Model:TM50-2D
Outline:
50×60
Range0~99
Unit
0.1S/1S/0.1M
1M/0.1H/1H
Selectable

ItemSpecification
Power Supply24VDC/AC or 90~265VAC 50/60Hz
Current Consumption5VA max.
Control OutputTwo time limit or time limit & instantaneous contact selectable
Output MethodTwo Relay 5A/250VAC
Control MethodPower on Delay
Output StatusTiming NO or NC selectable
Timing MethodIncreasing or decreasing timing selectable
Repetivity0.1% of F.S.
Setting Accuracy0.05% of F.S.
Reset Time0.1sec max.
Reset MethodPower off reset
Insulation Strength100MΩ/500VDC
Dielectric Strength2.5kV/ 1min.
Circumstance-20°C ~ +60°C , 35%~85%RH
Life of Relay20×106Times
50*60
TM50-3D TM Series Power On Delay Digital Timer
HELP_FILE: NO FILE
Discription:0.01S/0.1S/1S/0.1M/1M/0.1H/1H
Model:TM50-3D
Outline:
50×60
Range0~999
Unit
0.01S/0.1S/1S
0.1M/1M/0.1H/1H
Selectable

ItemSpecification
Power Supply24VDC/AC or 90~265VAC 50/60Hz
Current Consumption5VA max.
Control OutputTwo time limit or time limit & instantaneous contact selectable
Output MethodTwo Relay 5A/250VAC
Control MethodPower on Delay
Output StatusTiming NO or NC selectable
Timing MethodIncreasing or decreasing timing selectable
Repetivity0.1% of F.S.
Setting Accuracy0.05% of F.S.
Reset Time0.1sec max.
Reset MethodPower off reset
Insulation Strength100MΩ/500VDC
Dielectric Strength2.5kV/ 1min.
Circumstance-20°C ~ +60°C , 35%~85%RH
Life of Relay20×106Times
50*60
TM50-4D TM Series Power On Delay Digital Timer
HELP_FILE: NO FILE
Discription:0.01S/0.1S/1S/0.1M/1M/0.1H/1H/99M59S/99H59M
Model:TM50-4D
Outline:
50×60
Range0~9999
Unit
0.001S/0.01S/0.1S
1S/0.1M/1M/0.1H/1H
99M59S/99H59M
Selectable

ItemSpecification
Power Supply24VDC/AC or 90~265VAC 50/60Hz
Current Consumption5VA max.
Control OutputTwo time limit or time limit & instantaneous contact selectable
Output MethodTwo Relay 5A/250VAC
Control MethodPower on Delay
Output StatusTiming NO or NC selectable
Timing MethodIncreasing or decreasing timing selectable
Repetivity0.1% of F.S.
Setting Accuracy0.05% of F.S.
Reset Time0.1sec max.
Reset MethodPower off reset
Insulation Strength100MΩ/500VDC
Dielectric Strength2.5kV/ 1min.
Circumstance-20°C ~ +60°C , 35%~85%RH
Life of Relay20×106Times
60*50
TM60-3D TM Series Power On Delay Digital Timer
HELP_FILE: NO FILE
Discription:0.01S/0.1S/1S/0.1M/1M/0.1H/1H
Model:TM60-3D
Outline:
60×50
Range0~999
Unit
0.01S/0.1S/1S
0.1M/1M/0.1H/1H
Selectable

ItemSpecification
Power Supply24VDC/AC or 90~265VAC 50/60Hz
Current Consumption5VA max.
Control OutputTwo time limit or time limit & instantaneous contact selectable
Output MethodTwo Relay 5A/250VAC
Control MethodPower on Delay
Output StatusTiming NO or NC selectable
Timing MethodIncreasing or decreasing timing selectable
Repetivity0.1% of F.S.
Setting Accuracy0.05% of F.S.
Reset Time0.1sec max.
Reset MethodPower off reset
Insulation Strength100MΩ/500VDC
Dielectric Strength2.5kV/ 1min.
Circumstance-20°C ~ +60°C , 35%~85%RH
Life of Relay20×106Times
60*50
TM60-4D TM Series Power On Delay Digital Timer
HELP_FILE: NO FILE
Discription:0.01S/0.1S/1S/0.1M/1M/0.1H/1H/99M59S/99H59M
Model:TM60-4D
Outline:
60×50
Range0~9999
Unit
0.001S/0.01S/0.1S
1S/0.1M/1M/0.1H/1H
99M59S/99H59M
Selectable

ItemSpecification
Power Supply24VDC/AC or 90~265VAC 50/60Hz
Current Consumption5VA max.
Control OutputTwo time limit or time limit & instantaneous contact selectable
Output MethodTwo Relay 5A/250VAC
Control MethodPower on Delay
Output StatusTiming NO or NC selectable
Timing MethodIncreasing or decreasing timing selectable
Repetivity0.1% of F.S.
Setting Accuracy0.05% of F.S.
Reset Time0.1sec max.
Reset MethodPower off reset
Insulation Strength100MΩ/500VDC
Dielectric Strength2.5kV/ 1min.
Circumstance-20°C ~ +60°C , 35%~85%RH
Life of Relay20×106Times