Model |
TC72-AN-□-□
|
TC72-AA-□-□
|
TC72-AA-□-□-A
|
Alarm |
Non
|
Non
|
AL
|
Display |
Method
|
Non
|
Analog Deviation Meter
|
Tolerance
|
Non
|
1.0% of F.S.
|
Range
|
Non
|
±40°C
|
Setting |
Method
|
Trimmer (Variable Resister)
|
Tolerance
|
1.0% of Setting Range
|
Range
|
0~100 , 0~200 , 0~400 , 0~600 , 0~1200
|
General Data
|
Sensor Type |
K(CA) , J(IC) or PT-100Ω
|
Output Method |
Relay(5A/250VAC) , Voltage(20mA/12V) ,
Linear(4~20mA)
|
Control Method |
P+D ON/OFF , ON/OFF or Proportion
|
Proportion Band |
Appro 2.5% of F.S
|
Cycle Time |
2 Sec or 20Sec (ON+OFF)
|
Manual Reset |
Trimmer: Range±10°C
|
Unit of Degree |
°C or °F
|
AL Alarm
|
Setting Method |
Trimmer(AL)
|
Setting Range |
0 ~ +50° , 0 ~ -50° or -50° ~ +50° of
Setting Value
|
Output Method |
Relay , 0.5A/250VAC
|
HB Alarm
|
Setting Method |
Trimmer(HB)
|
Setting Range |
0.5A~25A ; 1.0A~50A
|
Output Method |
Relay , 0.5A/250VAC
|
Electrical Data
|
Power Supply |
110 / 220VAC ±20% 50/60Hz
|
Current Consumption |
2.5VA max.
|
Insulation Resistance |
Over 50MΩ/500VDC Between Power And Another
Terminal
|
Dielectrical Strength |
Over 2.5KV /1min Between Power And Another
Terminal
|
Mechanical Data
|
Operation Temp./Hum |
-20°C ~ +60°C ; 35%~85% RH
|
Vibration Resistance |
10 ~ 55Hz / 1.5mm , 2Hrs in X.Y.Z
Direction
|
Panel Thickness |
1.0 ~ 8.0mm
|
|