Single Preset
Counter |
|
HC-21P Digital Counter
HELP_FILE: NO FILE
Discription:2 digits
Model:HC-21P
Nr. of Displayer:2 Digits
Setting Range:1~99
Display Method:0.56"
7-Segment Red LED
Reponse Frequence:Contact
Input <60 cps ; Non-contact input <2.5K cps
Output Method:Relay Output
1a/1b , 5A/250VAC max. Voltage Output NPN , 150mA max.
Output Control:N.R.C control
Operating Voltage:110 /
220VAC ±20% , 50/60Hz
Current Consumption:5VA max.
Weight:Approx.650g.
General Specification
DC Power Supply:100mA/12VDC
Max.
Response Frequency:High Speed
<2.5Kcps ; Low Speed <60cps
Memory Method:Ni-Cd Battery
Output Control:N、R、C
(Selectable)
Contact Rated:5A / 250VAC
Max.
Dielectric Strength:Over
2.5KV / 1min , Between Power and Each Terminal
Operating Temp/Hum.:-20°C~+80°C
; 35%~85%RH
|
|
Single Preset
Counter |
|
HC-31P Digital Counter
HELP_FILE: NO FILE
Discription:3 digits
Model:HC-31P
Nr. of Displayer:3 Digits
Setting Range:1~999
Display Method:0.56"
7-Segment Red LED
Reponse Frequence:Contact
Input <60 cps ; Non-contact input <2.5K cps
Output Method:Relay Output
1a/1b , 5A/250VAC max. Voltage Output NPN , 150mA max.
Output Control:N.R.C control
Operating Voltage:110 /
220VAC ±20% , 50/60Hz
Current Consumption:5VA max.
Weight:Approx.650g.
General Specification
DC Power Supply:100mA/12VDC
Max.
Response Frequency:High Speed
<2.5Kcps ; Low Speed <60cps
Memory Method:Ni-Cd Battery
Output Control:N、R、C
(Selectable)
Contact Rated:5A / 250VAC
Max.
Dielectric Strength:Over
2.5KV / 1min , Between Power and Each Terminal
Operating Temp/Hum.:-20°C~+80°C
; 35%~85%RH
|
|
Single Preset
Counter |
|
HC-41P Digital Counter
HELP_FILE: NO FILE
Discription:4 digits
Model:HC-41P
Nr. of Displayer:4 Digits
Setting Range:1~9999
Display Method:0.36"
7-Segment Red LED
Reponse Frequence:Contact
Input <60 cps ; Non-contact input <2.5K cps
Output Method:Relay Output
1a/1b , 5A/250VAC max. Voltage Output NPN , 150mA max.
Output Control:N.R.C control
Operating Voltage:110 /
220VAC ±20% , 50/60Hz
Current Consumption:5VA max.
Weight:Approx.650g.
General Specification
DC Power Supply:100mA/12VDC
Max.
Response Frequency:High Speed
<2.5Kcps ; Low Speed <60cps
Memory Method:Ni-Cd Battery
Output Control:N、R、C
(Selectable)
Contact Rated:5A / 250VAC
Max.
Dielectric Strength:Over
2.5KV / 1min , Between Power and Each Terminal
Operating Temp/Hum.:-20°C~+80°C
; 35%~85%RH
|
|
Dual Preset
Counter |
|
HC-42P Digital Counter
HELP_FILE: NO FILE
Discription:4 digits
Model:HC-42P
Nr. of Displayer:4 Digits
Setting Range:
1 st 1~99999
2md 1~9999
Display Method:0.36" 7-Segment Red LED
Reponse Frequence:High Speed
<2.5K cps ; Low Speed <60 cps
Output Method:Two Relay , la
5A/250VAC
Output Control:N.R.C control
Operating Voltage:110 /
220VAC ±20% , 50/60Hz
Current Consumption:5VA max.
Weight:Approx.700g.
General Specification
DC Power Supply:100mA/12VDC
Max.
Response Frequency:High Speed
<2.5Kcps ; Low Speed <60cps
Memory Method:Ni-Cd Battery
Output Control:N、R、C
(Selectable)
Contact Rated:5A / 250VAC
Max.
Dielectric Strength:Over
2.5KV / 1min , Between Power and Each Terminal
Operating Temp/Hum.:-20°C~+80°C
; 35%~85%RH
|
|
Dual Preset
Counter |
|
HC-4T Digital Counter
HELP_FILE: NO FILE
Discription:4 digits
Model:HC-4T
Nr. of Displayer:4 Digits
Display Range:0000~9999
Display Method:0.56"
7-Segment Red LED
Reponse Frequence:Contact
Input <60 cps ; Non-contact input <2.5K cps
Operating Voltage:110/220VAC
±20% , 50/60Hz
Current Consumption:5VA max.
Weight:Approx.650g.
General Specification
DC Power Supply:100mA/12VDC
Max.
Response Frequency:High Speed
<2.5Kcps ; Low Speed <60cps
Memory Method:Ni-Cd Battery
Output Control:N、R、C
(Selectable)
Contact Rated:5A / 250VAC
Max.
Dielectric Strength:Over
2.5KV / 1min , Between Power and Each Terminal
Operating Temp/Hum.:-20°C~+80°C
; 35%~85%RH
|
|
Total Counter |
|
HC-51P Digital Counter
HELP_FILE: NO FILE
Discription:5 digits
Model:HC-51P
Nr. of Displayer:5 Digits
Setting Range:1~99999
Display Method:0.36"
7-Segment Red LED
Reponse Frequence:Contact
Input <60 cps ; Non-contact input <2.5K cps
Output Method:Relay Output
1a/1b , 5A/250VAC max. Voltage Output NPN , 150mA max.
Output Control:N.R.C control
Operating Voltage:110 /
220VAC ±20% , 50/60Hz
Current Consumption:5VA max.
Weight:Approx.650g.
General Specification
DC Power Supply:100mA/12VDC
Max.
Response Frequency:High Speed
<2.5Kcps ; Low Speed <60cps
Memory Method:Ni-Cd Battery
Output Control:N、R、C
(Selectable)
Contact Rated:5A / 250VAC
Max.
Dielectric Strength:Over
2.5KV / 1min , Between Power and Each Terminal
Operating Temp/Hum.:-20°C~+80°C
; 35%~85%RH
|
|
Dual Preset
Counter |
|
HC-52P Digital Counter
HELP_FILE: NO FILE
Discription:5 digits
Model:HC-52P
Nr. of Displayer:5 Digits
Setting Range:
1 st 1~99999
2 st 1~99999
Display Method:0.36" 7-Segment Red LED
Reponse Frequence:High Speed
<2.5K cps ; Low Speed <60 cps
Output Method:Two Relay , la
5A/250VAC
Output Control:N.R.C control
Operating Voltage:110 /
220VAC ±20% , 50/60Hz
Current Consumption:5VA max.
Weight:Approx.700g.
General Specification
DC Power Supply:100mA/12VDC
Max.
Response Frequency:High Speed
<2.5Kcps ; Low Speed <60cps
Memory Method:Ni-Cd Battery
Output Control:N、R、C
(Selectable)
Contact Rated:5A / 250VAC
Max.
Dielectric Strength:Over
2.5KV / 1min , Between Power and Each Terminal
Operating Temp/Hum.:-20°C~+80°C
; 35%~85%RH
|
|
Total Counter |
|
HC-5T Digital Counter
HELP_FILE: NO FILE
Discription:5 digits
Model:HC-5T
Nr. of Displayer:5 Digits
Display Range:00000~99999
Display Method:0.36"
7-Segment Red LED
Reponse Frequence:Contact
Input <60 cps ; Non-contact input <2.5K cps
Operating Voltage:110/220VAC
±20% , 50/60Hz
Current Consumption:5VA max.
Weight:Approx.650g.
General Specification
DC Power Supply:100mA/12VDC
Max.
Response Frequency:High Speed
<2.5Kcps ; Low Speed <60cps
Memory Method:Ni-Cd Battery
Output Control:N、R、C
(Selectable)
Contact Rated:5A / 250VAC
Max.
Dielectric Strength:Over
2.5KV / 1min , Between Power and Each Terminal
Operating Temp/Hum.:-20°C~+80°C
; 35%~85%RH
|
|
Single Preset
Counter |
|
HC-61P Digital Counter
HELP_FILE: NO FILE
Discription:6 digits
Model:HC-61P
Nr. of Displayer:6 Digits
Setting Range:1~999999
Display Method:0.36"
7-Segment Red LED
Reponse Frequence:Contact
Input <60 cps ; Non-contact input <2.5K cps
Output Method:Relay Output
1a/1b , 5A/250VAC max. Voltage Output NPN , 150mA max.
Output Control:N.R.C control
Operating Voltage:110 /
220VAC ±20% , 50/60Hz
Current Consumption:5VA max.
Weight:Approx.650g.
General Specification
DC Power Supply:100mA/12VDC
Max.
Response Frequency:High Speed
<2.5Kcps ; Low Speed <60cps
Memory Method:Ni-Cd Battery
Output Control:N、R、C
(Selectable)
Contact Rated:5A / 250VAC
Max.
Dielectric Strength:Over
2.5KV / 1min , Between Power and Each Terminal
Operating Temp/Hum.:-20°C~+80°C
; 35%~85%RH
|
|
Total Counter |
|
HC-6T Digital Counter
HELP_FILE: NO FILE
Discription:6 digits
Model:HC-6T
Nr. of Displayer:6 Digits
Display Range:000000~999999
Display Method:0.36"
7-Segment Red LED
Reponse Frequence:Contact
Input <60 cps ; Non-contact input <2.5K cps
Operating Voltage:110/220VAC
±20% , 50/60Hz
Current Consumption:5VA max.
Weight:Approx.650g.
General Specification
DC Power Supply:100mA/12VDC
Max.
Response Frequency:High Speed
<2.5Kcps ; Low Speed <60cps
Memory Method:Ni-Cd Battery
Output Control:N、R、C
(Selectable)
Contact Rated:5A / 250VAC
Max.
Dielectric Strength:Over
2.5KV / 1min , Between Power and Each Terminal
Operating Temp/Hum.:-20°C~+80°C
; 35%~85%RH
|
|